Silicone insulated copper cable RHO bare or tinned wire 6 meters lenght

 

•Extremely flexible

•Free of halogen and flame retardant

•Cable deliverable on rolls of 6 meters

•Single wire Cu ETP UNI EN 1977-78:2000

0,20 standard
0,10 on request

     You are in: Isolated braided shunts

Red Copper Tinned Copper Cross-Section
mm²
Ø Wire Ø
mm.
Currend flow
AC Amps
weight
Kg/mt
CCR   50/020 RHO CSS   50/020 RHO 50 0,20 15 200 0,60
CCR   70/020 RHO CSS   70/020 RHO 70 0,20 17 250 0,80
CCR 100/020 RHO CSS 100/020 RHO 100 0,20 20 300 1,15
CCR 120/020 RHO CSS 120/020 RHO 120 0,20 22 350 1,35
CCR 150/020 RHO CSS 150/020 RHO 150 0,20 24 400 1,70
CCR 200/020 RHO CSS 200/020 RHO 200 0,20 28 500 2,20
CCR 240/020 RHO CSS 240/020 RHO 240 0,20 30 600 2,65
CCR 300/020 RHO CSS 300/020 RHO 300 0,20 32 700 3,25

 

 

 

Caratteristiche isolante siliconico SYL:
SILICON – DYNASIL® Serie 1000
Low toxic fumes, opaque and self extinguishing in UL94V0
accordance with FS 304142 specification.
Insulation colour gray Sleeve thick 2 mm
Maximum temperature +250°C Dielectric strength >21 Kv/mm
Minimum temperature -50°C Reaction to fire (CSE) classe 1
Operating voltage 1000 V AC – 1500 V DC Smoke class determination F1
product: RHO REASIL Serie ME122
Requirements
Test required EN ISO 4589-2 EN ISO 5659-2 NF X 70-100-1/-2
Parameter LOI (%) (25 Kw/m² – Flaming) Ds max CIT
Values found 33.5 137 0.10
Acceptance limit per per per

R22 – R23

HL1: > 28%

HL2: > 28%

HL1: > 32%

R22             R23

HL1: < 600   HL1: < —-

HL2: < 300   HL1: < 600

HL1: < 150   HL1: < 300

R22              R23

HL1: < 1.2    HL1: < —-

HL2: < 0.9    HL1: < 1.8

HL1: < 0.75  HL1: < 1.5

The material complies with UNI EN 45545-2: 2015 requirements